XW series

XW

New product

The ultimate Emergency stop range with all the latest feature. Highest safety level provided thanks to IDEC's unique reverse energy structure and the fool-proof "Safe break action". Numerous options avaialble to fulfill all possible needs.

Main features

  • 3rd generation E-stop with IDEC's original "reverse energy control"
  • Unique "Safe Break action" : the contacts are held open if the button is not correctly fixed or damaged.
  • Two ways of resetting : pulling and turning
  • Very compact product (37.1mm deep behind panel with 4 contacts)
  • Numerous option including illumination linked to operation, size and color of the button, terminals...

More details

By phone

978-372-1602 East Coast
760-598-2518 West Coast

Monday – Friday 8am to 4pm

More info

Ergonomics 1

Ergonomics 2

Features

General specification

• Ø 16.2 mm mounting hole;
• 27.9 mm depth behind the panel for 1 to 4 contacts, illuminated or not;
• Two button sizes - Ø 29 mm & Ø 40 mm;
• Button colors - two red for emergency (Munsell 5R4/12 or 7,5R4,5/14) and yellow or grey for stop switch;
• Solder or PC board terminals;
• Direct opening action mechanism (IEC 60947-5-1, Annex K);
• Safety lock mechanism to prevent inadvertent operation;

Environmental specifications

• Operating temperatures: -25 to +60 °C (no freezing);
• Operating humidity: 45 to 85% RH (no condensation);
• Storage temperature : -45 to +80 °C;
• Degree of protection (IEC 60529): IP65,
• Vibration resistance :
Operating extremes : 10 to 500 Hz, amplitude 0,35 mm, acceleration : 50 m/s²
Damage limits : 10 to 500 Hz, amplitude 0,35 mm, acceleration : 50 m/s²
• Shock resistance :
Operating extremes : 150 m/s² maximum
Damage limits : 1,000 m/s² maximum

Electrical specifications

• Rated insulation voltage (Ui) : 300 V (illuminated part : 60V);
• Rated thermal current (Ith) : 5 A:
• 1 to 4 NC main contacts and 1 NO monitor contact;
• Contact resistance : 50 mohm max (initial value);
• Insulation resistance : 100 Mohm min (500V DC megger);
• Overvoltage Category : II (IEC 60664-1);
• Impulse Withstand Voltage : 2.5 kV (IEC60664-1/60947-5-1);
• Short-circuit Protection : 250V/10A fuse, (Type aM IEC60269-1, IEC602069-2)
• Electrical durability : 100,000 operations min - 250,000 @ 24V AC/DC, 100mA;
• Minimum applicable load : 5V AC/DC, 5 mA;

Materials

• Actuator : Plastic;

mechanical specifications

• Mechanical durability : 250,000 operations min;
• Push to lock : 10,5 N, Pull to reset : 10 N, Turn to reset : 0,16 Nm