XDGTY2MNNCNNPAN
The XDGTY2MNNCNNPAN Joystick is a versatile and reliable device that is perfect for a variety of applications. Its ergonomic Handle (Poignée/Handgriff/控制杆) ensures comfortable and precise control, allowing users to easily navigate through different functions. The advanced Spring centering (Retour au centre/Rückstellung/定心) mechanism ensures that the joystick returns to its neutral position when released, providing optimal stability and accuracy. With an Operating Force (Force de fonctionnement/Betriebskraft/操作力) of 124Nm, this joystick offers smooth and effortless operation. Its SAE CAN bus J1939 71 Output (Sortie/Ausgang/输出) allows for seamless integration with other devices and systems. The XDGTY2MNNCNNPAN Joystick features a convenient Operator Presence Paddle (Palette de présence de l'opérateur/Fahrerpräsenzpaddel/操作员检测摇杆) for enhanced safety and control. Additionally, the inclusion of a two pushbuttons and a Hall effect thumbwheel on the Faceplate (Façade/Frontplatte/面板) provides additional functionality and customization options. Upgrade your control system with the XDGTY2MNNCNNPAN Joystick today!
Key Features
- Operator Presence Paddle: No
- Handle: GT
- Centering: Spring centering
- Index Trigger: No
- Operation: One axis, Y
- Mechanical: None ²
- Series: XD
- Operating Force: 1.24Nm
Specifications
Distinctive Features:
- SIL 2 compatible - Redundant Hall sensors
- Resists high axial load (1780 N - 400 lbf)
- Shallow mounting depth of <60 mm (2.36)
- Rated for 10 million lifecycles
- SAE CAN bus J1939-71
General Specifications:
- Operating Temperature: -40 °C to +85 °C (-40 °F to +185 °F)
- Storage Temperature: -40 °C to +85 °C (-40 °F to +185 °F)
- Above Panel Sealing: Up to IP67/IP69K (subject to handleconfiguration)
- Humidity: IEC 60068-2-38
- Thermal shock: SAE J1455 section 4.1.3.2
- Salt spray: IEC 60068-2-11
Environmental Specifications:
- Random vibration: IEC 60068-2-64
- Sinusoidal vibration: IEC 60068-2-6
- EMS Emissions:- Radiated Emissions Level: ECE/324/Add.9:2012 CISPR 25:2002- Radiated Emissions Level: CISPR 25:2008
- EMS Immunity:- ESD: ISC 10605:2008 criteria A- Radiated immunity: ISO 11452-2:2004 criteria B- Bulk current injection immunity: ISO 11452-4:201 criteria A- Pulse 1, Pulse 2a, Pulse 2b, Pulse 3a, Pulse 3b, Pulse 4, Pulse 5a:ISO 7637-2:2011 criteria A
Electrical Specifications:
- Technology: Redundant Hall effect sensors
- Supply voltage range: 6 - 35 VDC
- Transient overvoltage max: 40 V
- Reverse polarity Max: -1000 VDC
- Output signal: SAE CAN bus J1939-71
- Connections: Deutsch DTM04-6p
- Six position connector: Deutsch DTM04-6P
- Wire: 22 AWG, PTFE insulation with expandable sleeve
- Length: 6.00” +/- 0.5” (bottom of joystick to connector)
Added to Your Cart