EU2B series - E-stops

EU2B series - E-stops Agrandir l'image

EU2B E-stop

Nouveau produit

Ideal for applications in hazardous locations with explosive gases, such as oil & gas, petrochemical, painting and more. 




Main features 



  • Hazardous location qualified and certified : Zone 1/Zone 21, division 2

  • Applicable in explosive gas atmospheres (Ex de IIC T6 Gb),

  • Applicable in explosive dust atmospheres (Ex tb IIIC Db IP65),

  • Two ways of resetting - pulling and turning,

  • Up to 3 contact block

Plus de détails

Besoin de conseils

Demande de devis

0820 20 30 10

Lundi au vendredi de 9h à 17h

Téléchargement
En savoir plus

Ergonomie 1

Ergonomie 2

Caractéristiques

Spécifications générales

• Ø 30.5 mm mounting hole;
• Panel thickness: 1 to 4.5 mm
• 67.7 mm depth (plastic bezel);
• Button size - Ø 40 mm;
• Button color - red
• Way of resetting - pulling;
• IP2X Screw terminal
• Direct opening action mechanism (IEC 60,947-5-1, Annex K);
• Safety lock mechanism to prevent inadvertent operation;

Spécifications environnementales

• Operating temperatures: -20 to +50 °C (no freezing);
• Operating Humidity: 45 to 85% RH (no condensation);
• Hazardous location, class 1, Zone 1/division 2;
• Degree of protection (IEC 60529): IP65;
• Vibration resistance :
Operating extremes : 5 to 500 Hz, amplitude 0,35 mm, acceleration 50m/s²
Damage limits : 5 to 500 Hz, amplitude 0,35 mm, acceleration 50m/s²
• Shock resistance :
Operating extremes : 150 m/s² maximum
Damage limits : 1,000 m/s² maximum

Spécifications électriques

• Rated insulation voltage (Ui) : 600 V;
• Rated thermal current (Ith) : 10 A:
• Up to 3 contacts;
• Contact resistance : 50 mohm max (initial value);
• Insulation resistance : 100 Mohm min (500V DC megger);
• Impulse withstand voltage : 6kV
• Short-circuit Protection : 250V/10A fuse, (Type aM IEC60269-1, IEC602069-2)
• Mechanical durability : 50,000 operations min;
• Electrical durability : 50,000 operations min;
• Minimum applicable load : 3V AC/DC, 5 mA;

Matériaux

• Actuator : Plastic

Spécifications mécaniques

• Mechanical durability : 50,000 operations min;

Homologations

  • UL

Plus de 65 ans d'expérience

Un support client international

La plus large gamme d'IHM (composants & solutions)

Des process industriels intégrés

Une innovation constante

Besoin d'aide ?
Contactez-nous par tel, email ou livechat !

Demande de rappel